KLIXON® C series thermal breakers are designed to protect wiring and meet the harshest environmental requirements. The C series closed construction circuit breakers are weatherproof sealed for protection against…
Our engineering team reviews your quote and sample requests against your project's technical specification and required quantities. We respond within 24 hours at the latest with a formal quotation, delivery schedule and, where applicable, alternative configuration proposals.
KLIXON® C series thermal breakers are designed to protect wiring and meet the harshest environmental requirements. The C series closed construction circuit breakers are weatherproof sealed for protection against moisture, dust, grease, fuel vapors and other harsh environments.
Features
| Calibration : 200% rated current, 77°F (25°C) | 2 to 10 amps : 20 to 150 seconds 12.5 to 40 amps : 5 to 55 seconds | ||
| Ultimate Trip At 77°F (25°C) | Must hold 100%, Must trip 135% | ||
| Endurance | Per SAE J553 | ||
| Interrupt Current Capacity | Per SAE J553 and ABYC E-11 | ||
| Vibration | 10G MIL-STD-202 Method 204, Condition A | ||
| Mechanical Shock | MIL-STD-202 Method 101D (sealed only) | ||
| Dielectric Strength | MIL-STD-202 Method 301, 1500VAC min | ||
| Insulation Resistance | MIL-STD-202 Method 302, Condition B, 100MΩ min | ||
| Weight (with mounting nuts) | CDM: 48 grams max CDA: 41 grams max CM : 37 grams max CA : 32 grams max |