Qualified products from world-leading brands in HMI, switch, sensor and connectivity solutions.
All CategoriesContact our team for the right product and technical support for your application.
Contact Us
KLIXON® S series thermal breakers are designed to protect wiring and meet the harshest environmental requirements. The sealed circuit breakers are weatherproof for protection against moisture, dust, grease, fuel vapors…
Our engineering team reviews your quote and sample requests against your project's technical specification and required quantities. We respond within 24 hours at the latest with a formal quotation, delivery schedule and, where applicable, alternative configuration proposals.
KLIXON® S series thermal breakers are designed to protect wiring and meet the harshest environmental requirements. The sealed circuit breakers are weatherproof for protection against moisture, dust, grease, fuel vapors and other harsh environments. The S series breakers are lightweight and designed to interrupt short circuits or overloads and combine trip-free protection with fast response time.
Features
| Calibration : 200% rated current, 77°F (25°C) | 35 to 150 Amps : 8 to 100 seconds | ||
| Ultimate Trip At 77°F (25°C) | Must hold 100%, Must trip 135% | ||
| Endurance | Per SAE J1625 | ||
| Interrupt Current Capacity | Per SAE J1625 and ABYC E-11 | ||
| Vibration | 10G MIL-STD-202 Method 204, Condition A | ||
| Mechanical Shock | Per SAE J1455, 4G’s, 10-2K Hz | ||
| Voltage Breakdown | Per SAE J1625 500VAC | ||
| Salt Spray | Per SAE J1625, 96 hours | ||
| Voltage Drop | Per SAE J1625 | ||
| Weight (with mounting nuts) | SDLM (A) : 75 grams (71 grams) max SLA : 62 grams max |