Home Products Panel Switches Emergency Stops XA UNIBODY SERIES
APEM

XA UNIBODY SERIES

A very compact product. The X6 range includes the patented IDEC "Reverse energy structure" which opens the contact in case the button is damaged. Reset is done by either pulling or twisting the button.

Manufacturer
APEM
Part No
XA1E
Category
Emergency Stops

Our engineering team reviews your quote and sample requests against your project's technical specification and required quantities. We respond within 24 hours at the latest with a formal quotation, delivery schedule and, where applicable, alternative configuration proposals.

Overview

A very compact product. The X6 range includes the patented IDEC "Reverse energy structure" which opens the contact in case the button is damaged. Reset is done by either pulling or twisting the button.

MAIN FEATURES

3rd generation E-stop with IDEC's original "Reverse energy structure"

Requires only Ø 16 mm x 19.5 mm for installation

Two ways of resetting - pulling and turning,

Gold-plated crossbar contacts,

Fully qualified and certified;

FEATURES

GENERAL SPECIFICATION

• Ø16.2 mm mounting hole;
• 19.5 mm depth (Solder terminal) or 23.9mm depth (Solder/tab terminal) behind the panel;
• Two button sizes - Ø 30 mm & Ø 40 mm;
• Two button colors - red for emergency and yellow for stop switch;
• Two ways of resetting - pulling and turning;
• Solder or solder/tab terminal #110 for easy connections;
• Direct opening action mechanism (IEC 60947-5-5 §5.2, IEC 60947-5-1, Annex K);
• Safety lock mechanism to prevent inadvertent operation (IEC 60947-5-5, §6.2);

ENVIRONMENTAL SPECIFICATIONS

• Operating temperatures: -25 to +60 °C (no freezing);
• Operating humidity: 45 to 85% RH (no condensation);
• Storage temperatures: -45 to +80 °C;
• Degree of protection (IEC 60529): IP65
• Vibration resistance:
Operating extremes: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s²;
Damage limits: 10 to 500 Hz, amplitude 0.35 mm, acceleration 50 m/s²;
• Shock resistance:
Operating extremes: 150 m/s² maximum
Damage limits: 1,000 m/s² maximum

ELECTRICAL SPECIFICATIONS

• Rated insulation voltage (Ui): 250 V;
• Rated thermal current (Ith): 5 A:
• Up to 2 NC contacts
• Contact resistance: 50 mohm max (initial value);
• Insulation resistance: 100 Mohm min (500 V DC megger);
• Overvoltage Category: II (IEC 60664-1);
• Impulse Withstand Voltage: 2.5 kV (IEC60664-1/60947-5-1);
• Short-circuit Protection: 250 V/10 A fuse, (Type aM IEC60269-1, IEC60269-2)
• Electrical durability : 100,000 operations min;
• Minimum applicable load : 5 V AC/DC, 1 mA;

MATERIALS

• Actuator : Plastic;
• Contact : gold-plated

MECHANICAL SPECIFICATIONS

• Mechanical durability : 1,000,000 operations min;
• Push to lock : 10.5 N, Pull to reset : 10 N, Turn to reset : 0.16 Nm